Specialized production factory

Current Location >> Homepage >> Ion Chromatography
PIC—10 Ion Chromatography
 


PIC-10 Ion Chromatography  Automatic Integrated Structure  

 Adopted advanced tech in the world and automatic integrated machine, it has following characteristics:

·Mainframe adopts 5.7inches high resolution large screen display

Display conductance value, current value, pump pressure, flux and temperature, analyze spectra online, display spectra, peak and peak area (the numbers are real-time values) which is incomparable in China and can be used without computer.

Realize man-machine conversation via screen, mouse or LCD touch screen, set all working parameters, automatic stalls election and adjustment to control working state of conductance checker, volt-ampere checker, high-pressure stratospheric pump and workstation.

·Integrated Structure

Drawing 1 Combine conductance checker, volt-ampere checker, high pressure stratospheric pump, workstation, constant temperature system and online degassing, negative and positive ion analysis can be finished at one time if positive ion isolation column is equipped. Users can choose according to requests.

 

Drawing 2 Combine dual conductance checker, dual high-pressure infusion pump, dual sampling valve (manual or automatic), dual isolation columns and dual passages workstation. Negative and positive ion can be analyzed at one time.

·Workstation can be equipped

Connect with special microcomputer via internet interface to realize data treatment and remote control of instrument

·Automatic sampling device can be equipped

Connect with mainframe via special part, automatic sampling and automatic memory can be finished

·Overall Dimension of Mainframe

Length (330mm)×Width (415mm)×Height (500mm)

Technical Index

·Item:

Negative ion: F-, SiO32-, CIO2-, BrO3-, CI- NO2-, SeO3-, Br-, CIO3- ,NO3-, HPO42-, SO32-, SO42-, TeO42- , SeO42-, AsO43-, I-, S2-, CN-, MoO42- , WO42-, CrO42-, lactic acid, formic acid, Methanesulfonate, PTSA, Sulfonic acid methyl acrylamide, acetic acid, Propionate, Glycolic Acid, pyruvic acid, valeric acid, A Chloroacetate, tartaric acid, malic acid, Oxalate, Benzoic Acid, Sorbic acid and Glyphosate, etc.

Positive ion: Li+, Na+, NH4+, K+, Rb+, Cs+ , Mg2+, Ca2+, Sr+, Ba2+ , Ni2+, Cu2+, Pb2+, Zn2+, Fe2+, Mn2+, Cd2+, A methylamine, Dimethylamine, Trimethylamine, lycine and Choline Chloride, etc.

Conductance Checker

Adopt precise five-pole conductance checker, divided into one route and dual route system. While adopting dual route system, negative ion and positive ion can adopt sequential recycling electrochemical inhibition, positive ion can adopt non-inhibition method, it has high agility for restraint method and easy operation advantages for non-inhibition method.

 

Main Technical Performance

Five-pole conductance battery: loop passive 316 stainless steel electrode, volume≤1.2ul. Temperature constant device, constant temperature precision: 5 to 50℃±0.05℃

Resolution: not lower than 1/20000(≤0.025ns)

Basic noise: not higher than 0.6Fs

Baseline shift: not exceed±2.0Fs

Range: 03500us, manual and automatic function

Output voltage:01000mv.

Automatic adjustable range:-1000mv~+1000mv.

Constant current of suppresser: 0150mA., increment 1mA, set by users on screen

Fit for various inorganic negative iron, organic acid, alkali metals, alkaline earth, ammonium ions

·Ampere checker:

Four checkout methods: DC ampere, impulse ampere, integral ampere, differential coefficient volt-ampere method

Adopt flow method or flow injection method, above four methods can be finished after choosing proper electrode, fit for negative ion of iodine, sulfur, cyanogens and bromine, etc., positive ion of lead, copper, zinc and cadmium, as well as organic substances.

Range:1μg/L1mg/L

Lower limit: Br- 15μg/L, I- 5μg/L, S2- 5μg/L, CN- 5μg/L, Cu2+ 0.5μg/L, Zn2+ 1μg/L, Pb2+ 0.2μg/L, Cd2+ 0.1μg/L.

·High-pressure Infusion Pump

It is dual pistons Reciprocating pumps controlled by microcomputer, buffer and pressure sensor is equipped for flowing path so that impulsion of pump lowers to its most. Pump can work under ultrahigh pressure depending on advanced airproofing technique. We can provide imported pump or assembled pump made by Germany, users can choose freely.

 

Domestic pump(key parts are imported)

Imported pump made by Germany

Pressure range

042.0MpaStainless steel

035.0MpaPEEK

040.0Mpa

 

Flux range

0.019.99mL/min

0.0019.999mL/min

Flux error

precision

RSD2%

RSD0.5%

Repeatability error

Stability

±1%

±0.2%

Pressure sensor

Pressure precision 0.1Mpa

Pressure precision 0.1Mpa

Overvoltage protection

Pump will close and give alarm if working pressure is too high or too low

Pump will close and give alarm if working pressure is too high or too low

Pump flow path materials

PEEK or stainless steelusers can choose freely

Biological titanium steel or stainless steel, users can choose freely

 

 

Domestic pump(key parts are imported)

Imported pump made by Germany

Pressure range

042.0MpaStainless steel

035.0MpaPEEK

040.0Mpa

Flux range


0.01
9.99mL/min


0.001
9.999mL/min

Flux error

precision

RSD2%

RSD0.5%


Repeatability error

Stability

±1%

±0.2%

Pressure sensor

Pressure precision 0.1Mpa

Pressure precision 0.1Mpa

Overvoltage protection

Pump will close and give alarm if working pressure is too high or too low

Pump will close and give alarm if working pressure is too high or too low

Pump flow path materials


PEEK or stainless steel
users can choose freely

Biological titanium steel or stainless steel, users can choose freely

 

 

 

Remark: 050Mpa pressure is available for special requests (stainless steel)

·Flow Path System

Adopt best parts in the world, pressure resistance of sampling valve reaches 7000psi, tie-in and flow path are made of PEEK materials (imported parts) with general purposes, cleaning agent made of strong acid and alkali is available, soluble to organic solvent which is convenient for users to analyze complicated samples, clean and repair chromatogram column. Users can change columns and proper cleaning agent freely. Higher pressure avoids leaks of flow path so that users have no worries at all.

Rated pipe of manual or automatic sampling valve can be set from 25µl to 200µl according to requests of users.

·Fit for chromatogram column with different requests

We provide many chromatogram columns for users (from Japan Shodex, America Alltech and domestic column, etc.), users can choose various negative and positive chromatogram columns, negative and positive ion protection column according to different requests of users.

·Chromatogram Column and Conductance Battery Constant Temperature System

Temperature has great influence on mobility and conductance of ion, conductance value will enhance 2% if temperature rises 1℃. In addition, temperature can modify isolation of iron in Chromatogram Column. Thus, precise temperature control towards column and box (Chromatogram Column, conductance battery) can gain good isolation and guarantee. Instrument box adopts dual layer structure with insulated layer, equipped with constant temperature system (semiconductor constant temperature tank), temperature ranges from 5 to 50℃. Temperature precision ±0.05℃. users can choose according to their working state.

·Most advanced inhibition tech in the world

Sequential automatic recycled electrochemical suppresser, automatic recycling online, easy operation, long service life. In addition, water suppresser and chemical suppresser can be collocated according to requests

·Online degassing function

Gas can be removed making use of vacuum principle (vacuum pressure -0.01MPa) in order to enhance agility and stability of instrument, operation will be easier. Users can choose according to their working state.

·Chromatogram workstation

24 High-precision High-agility ADC

Transmit digital signal with computer via high performance USB method, Windows2000 or WindowsXP interface. Easy operation, intelligent treatment of spectrum data to show drawing, period, peak height, area and concentration, make and rectify curve.

Possess professional functions, there are still easy adjustable methods if special effects are necessary.

Simple and proper interface layout; print, result collection, sequential operation, automatic save and spectrum management are available. Spectrum collects data and related data to gather into one doc according to GLP criteria.

This software is linked closely to Microsoft Office and it can produce analysis report in Word. Rated results (or collection of rated results for many times) can be clipped and transmitted to Excel, analysis records can be stored into Access database directly.

Remote control can be realized via internet instrument, working parameters can be set online to carry out man-machine conversation to control automatic sampling machine

Automatic checker can give alarm and protect instrument if there are malfunctions while running.

Data collection and treatment of negative and positive data can be finished at one time for using dual passages workstation.

Working State

Power supply: AC220V±10%  50HZ

Ambient temperature: 10~30℃

Relative humidity: 25~85%

 

PIC—10 Checkout Technical Index   

Analyze inorganic negative ion (Sequential Automatic Recycling Electrochemical Suppresser)

Separation

Sample and check Formic acid, ClO2-, ClO3-, F-, CI-, NO2-, HPO42-, Br-, NO3-, SO42-, BrO3-

Lower limit

Better than 0.1ppb(CI- test)

Analysis reproducible

Better than 1.0%SO42- test

Linearity range

>103

 

 Analyze inorganic positive ion(Sequential Automatic Recycling Electrochemical Suppresser)

Separation

Sample and check Li+, Na+, NH4+, K+ , Ca2+, Mg2+, Sr2+, Ba2+ ion one time

Lower limit

Better than 2ppbNa+ test

Analysis reproducible

Better than 2%Na+ test

Linearity range

>102

 

Analyze Positive Ion (non-inhibition Type)

Separation

Sample and check Li+, Na+, NH4+, K+, Ca2+ , Mg2+, Sr2+, Ba2+, Ni2+, Zn2+, Co2+ ion, etc.

Lower limit

Na+ Better than 15ppbMg2+ Better than 20ppb, Ca2+ Better than 30ppb

Analysis reproducible

Better than 2%Na+ test

Linearity range

>102

Remark: above indexes are brought from imported iron chromatogram column

Time:2007-8-31
Category:
Keyword:
ALL RIGHTS RESERVED Qingdao P.uren Instrument Co., Ltd. All characters and pictures are not allowable to copy

Add: Business Buidling, No.23 Siliu Northern Road, Licang District Tel: 86-0532-87060928 Fax: 0532-87622298 P.C:266043
                                    Website:www.qdpr.com Email:pr@qdpr.com

鲁ICP备05033022号